Static structural analysis is the most common job in Ansys Workbench: working out how much a part deflects and how highly it is stressed under steady loads. The software makes it easy to get a colourful result. Getting a result you can trust takes a few extra steps that many tutorials skip.
This guide walks through a static structural analysis in Ansys Workbench step by step, from geometry to results, with the checks we use on every project. The cover shows a static structural analysis we ran for this guide: a 10 mm steel corner bracket held at two bolt holes, with a 5 kN bearing load at its tip hole.
It calculates deformation, stress, strain, reaction forces and safety factors for loads that do not change with time, such as weights, pressures, bolt preloads and steady forces. It is not the right tool for:
In the Workbench Project Schematic, drag a Static Structural system from the Toolbox. It creates a chain of cells: Engineering Data, Geometry, Model, Setup, Solution and Results. Set the unit system you will work in early (for example millimetres, newtons and seconds) so loads and results are read correctly.
Workbench detects contacts automatically and makes them bonded by default, gluing the parts together. That is right for welded or glued joints, but wrong for parts that can slide or separate:
In our FEA of a bolted flange joint, the bolts were preloaded to about 1,350 kN in a first load step before 2.07 MPa of internal pressure was applied, so the contact pressure on the gasket could be checked properly.
In our FEA of a nylon injection-moulded bracket, the mesh was refined around the fillets, load-bearing supports and mounting hole, where the stresses peak.
On the corner bracket on this page's cover, the stress peaks at about 204 MPa beside the loaded hole, with smaller peaks at the rounded inner corner and around the lightening hole, while the maximum deflection is only 0.18 mm. Against a typical structural steel yield of about 250 MPa, that is a safety factor of about 1.2 at the hottest spot. A peak right where a load is applied always deserves a second look: is it a real bearing stress, or a result of how the load was modelled?
In our FEA of a beam bracket in Ansys 2024 R2, the total deformation peaked at about 0.35 mm around the central opening. In our FEA of a battery module frame, the safety factor plot showed most of the frame was fine, but one small region near the lower mounting area dropped to about 0.41.
Workbench is the project environment that links the steps together. Ansys Mechanical is the application inside it where you set up the model, mesh, loads and results for structural analyses.
Most likely a singularity at a sharp corner, point load or fixed edge. Add the real fillet radius or judge the stress a short distance away, and check whether it converges as the mesh is refined.
No. Ansys Student is licensed for learning and academic use only, so commercial projects need a commercial licence or a consultant who has one.
Yes. We review the setup, mesh, contacts and boundary conditions, and confirm whether the results can be trusted.
Send your CAD files, loads and requirements through our contact page. We will reply with a scope, timeline and quote.
Our engineers run static structural, nonlinear, thermal and dynamic analyses in Ansys every day, and can take on your analysis or review one your team has set up. Send us your CAD files and requirements, and we will reply with a clear scope and quote.